Image

Textile and glass barriers for containment and channeling of toxic smoke and hot gases generated in a fire

Classifications and descriptions

Kortex Smoke Fix

Classification DA 180 minutes ay 600 ºC

Fiberglass Fabric Type Kortex fv

Resistant to hot smoke and toxic gases generated in a fire

Use in industrial buildings or buildings where aesthetics are not priority.

Counterweight system by round steel bar or steel cable so that the result is a continuous clamping linearly.

SSB system

 

Kortex Smoke DA automatic

Classification DA 180 minutes at 600 ºC

Woven in fiberglass reinforced steel type Kortex β

Resistant to hot smoke and toxic gases generated in a fire

Use in buildings where the barrier must be architecturally integrated.

Counterweight self-leveling system.

Asb3 "gravity Safety" Mode.

“Drop Controller " mechanism: mechanical speed control integrated in barrier shaft and tested under fire environment.

Kortex Smoke DHA

Classification DHA 180 minutes at 1000 ºC

Woven in fiberglass reinforced steel type Kortex β

Resistant to hot smoke and toxic gases generated in a state of temperatures up to 1,000 ºC.

Triple reinforcement seams avoiding weak points.

Watertight guidance system with anti-lock preventing obstructions in the up and down maneuvers.

“Drop Controller " mechanism: mechanical speed control integrated in barrier shaft and tested under fire environment.

Kortex Glass

Classification DA 120 minutes at 600 ºC

SSB glass barrier for controlling toxic smoke and hot gases generated in a fire.

For places where high architectural demand is paramount.

With a universal anchoring system for all types of surfaces, it makes the value for money the best on the market in terms of gas containment solutions in SCTEH systems.

Objetive


Pipeline screens to prevent spillage of fumes


Prevent human loss and material damage from gases


Facilitate tasks for extinguishing teams while maintaining visibility


Keep evacuation routes clean


Perimeter closure of adjacent spaces avoiding spills inside plants in the rise of hot fumes and gases

Application

Industrial Sector
Logistics Sector
Buildings With Atriums
Public Attendance Buildings
Shopping Malls
Parking

Tests and approvals

UNE EN 1363 - 1

Fire resistance testing - Part 1: general requirements

UNE EN 13501-4+A1

Classification according to the fire behavior of construction products and building elements. Part 4: classification from data obtained from fire resistance tests of components of smoke control systems

UNE EN 12101-1+A1

Smoke and heat control systems-Part 1: specifications for smoke control barriers

Certificate of proof of benefits

  UNE-EN 12101-2 ANNEX ZA.3

C/ Invención, 11 · P.I. Los Olivos